A Preclinical Feasibility Study of Endoscopic Barostat: A Possible Diagnostic Tool for Visceral Hypersensitivity in
Yuki Ushimaru1,2, Tatsuhiro Masaoka3,4, Noriko Matsuura5
1Department of Next Generation Endoscopic Intervention (Project ENGINE), Osaka University Graduate School of Medicine, Osaka, Japan.
Introduction:
Diagnosing functional dyspepsia requires excluding organic disease and gastrointestinal function evaluation; however, there are no modalities to evaluate these simultaneously. This preclinical study examined the possibility of an endoscopic barostat.
Methods:
Ultrathin endoscopy and our newly developed pressure-regulated endoscopic insufflator, which insufflates the gastrointestinal tract until the preset pressure is achieved, were used. The actual intragastric pressure was measured using an optical fiber manometer placed in the stomach. Experiment-1: in an ex vivo experiment, we insufflated the isolated stomach and verified whether the intragastric pressure reached the preset pressure. Experiment-2: we inserted the endoscope orally in a porcine stomach, insufflated the stomach, and verified whether the intragastric pressure reached the preset pressure. Finally, we insufflated the stomach at a random pressure to verify the functional tests for proof-of-concept.
Results:
Experiment-1: the intragastric pressure reached the preset pressure. After reaching the plateau, the pressure remained stable at the preset pressure (Huber M value: 1.015, regression line: 0.988, 95% confidence interval [CI]: 0.994-0.994). Experiment-2: the intragastric pressure reached the preset pressure. After reaching the plateau, the pressure remained stable at the preset pressure (Huber M value: 1.018, regression line: 0.971, 95% CI: 0.985-0.986). At randomly preset pressures, the transendoscopic theoretical intragastric pressure detected by using the insufflator was correlated with the actual pressure measured by using the pressure manometer.
Conclusions:
This proof-of-concept study shows that a pressure-regulated endoscopic insufflator provides stable intragastric pressure at the preset level, with the potential of an endoscopic barostat to assess the visceral hypersensitivity related to functional dyspepsia.
More Related Videos
Related Concept Videos
Peptic Ulcer Disease III: Clinical Manifestations and Diagnostic Studies
Few clinical manifestations differentiate gastric ulcers from duodenal ulcers. Distinctions in the location, timing, and pain relief are crucial for healthcare providers in differentiating between gastric and duodenal ulcers during clinical assessments.
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Barrett Esophagus-II: Clinical Manifestations and Management
To diagnose Barrett's esophagus, healthcare providers often recommend an endoscopy for those showing symptoms of acid reflux. The procedure...
Endoscopic Procedures V: ERCP
Patient...