Related Experiment Video
Updated: Oct 15, 2025

Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
Advancing PPG Signal Quality and Know-How Through Knowledge Translation-From Experts to Student and Researcher
Samuel Huthart1, Mohamed Elgendi2, Dingchang Zheng3
1Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom.
Abstract:
Objective: Despite the vast number of photoplethysmography (PPG) research publications and growing demands for such sensing in Digital and Wearable Health platforms, there appears little published on signal quality expectations for morphological pulse analysis. Aim: to determine a consensus regarding the minimum number of undistorted i.e., diagnostic quality pulses required, as well as a threshold proportion of noisy beats for recording rejection. Approach: Questionnaire distributed to international fellow researchers in skin contact PPG measurements on signal quality expectations and associated factors concerning recording length, expected artifact-free pulses ("diagnostic quality") in a trace, proportion of trace having artifact to justify excluding/repeating measurements, minimum beats required, and number of respiratory cycles. Main Results: 18 (of 26) PPG researchers responded. Modal range estimates considered a 2-min recording time as target for morphological analysis. Respondents expected a recording to have 86-95% of diagnostic quality pulses, at least 11-20 sequential pulses of diagnostic quality and advocated a 26-50% noise threshold for recording rejection. There were broader responses found for the required number of undistorted beats (although a modal range of 51-60 beats for both finger and toe sites was indicated). Significance: For morphological PPG pulse wave analysis recording acceptability was indicated if <50% of beats have artifact and preferably that a minimum of 50 non-distorted PPG pulses are present (with at least 11-20 sequential) to be of diagnostic quality. Estimates from this knowledge transfer exercise should help inform students and researchers as a guide in standards development for PPG study design.
More Related Videos
13:44Project-Based Learning Guidelines for Health Sciences Students: An Analysis with Data Mining and Qualitative Techniques
Published on: December 9, 2022
09:55Bridging the Technology Divide in the COVID-19 Era: Using Virtual Outreach to Expose Middle and High School Students to Imaging Technology
Published on: September 28, 2022
Related Concept Videos
Improving Translational Accuracy
Signal Transduction: Overview
Typically, signal transduction involves three...
Upsampling
Synaptic Signaling
Amplifying Signals via Second Messengers