Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
A simple technique for the traditional method to estimate mean radiant temperature
Hyunjung Lee1,2, Sangman Jo2, Sookuk Park3
1Department of Urban Climatology, Office for Environmental Protection, City of Stuttgart, 70182, Stuttgart, Germany.
A new simple method accurately estimates mean radiant temperature (Tmrt), a key factor in urban thermal comfort. This traditional method (Tmrt_TM) shows high accuracy, especially when refined with regression equations, making it reliable for comfort studies.
Area of Science:
- Environmental Science
- Urban Climatology
- Human Thermal Comfort
Background:
- Mean radiant temperature (Tmrt) is crucial for human thermal comfort in urban environments.
- Existing Tmrt estimation methods vary in accuracy, necessitating simpler, reliable techniques.
- Accurate Tmrt assessment is vital for understanding and improving urban thermal conditions.
Purpose of the Study:
- To present and validate a simple technique for estimating mean radiant temperature (Tmrt) based on the traditional method (Tmrt_TM).
- To compare the accuracy of Tmrt_TM against the six-directional method (Tmrt_SM) and black globe thermometer methods (Tmrt_BG, Tmrt_BGv).
- To develop regression equations to enhance the accuracy of the Tmrt_TM method.
Main Methods:
- Utilized measured radiation data from radiometers to estimate Tmrt using the traditional method (Tmrt_TM).
- Validated Tmrt_TM against Tmrt_SM, Tmrt_BG, and Tmrt_BGv at two urban stations in Jeju, Republic of Korea.
- Collected data over 8 days during spring and summer, encompassing sunny and cloudy conditions.
Main Results:
- Tmrt_TM showed mean differences within ISO 7726 comfort accuracy (±2 ℃) on sunny days, improving to 0.1-0.3 ℃ in high Tmrt conditions.
- Black globe thermometer methods (Tmrt_BG and Tmrt_BGv) exhibited larger deviations, exceeding thermal stress accuracy limits (±5 ℃).
- Highly significant correlations (r=0.93) were found between Tmrt_TM and Tmrt_SM; developed regression equations reduced mean differences to <0.5 ℃ with r2 >0.87.
Conclusions:
- The simple Tmrt_TM technique is accurate and reliable for estimating mean radiant temperature in human thermal comfort studies.
- Black globe thermometer methods require careful application, particularly on sunny days, due to potential inaccuracies.
- Refined Tmrt_TM using regression equations offers a precise and practical approach for urban thermal environment assessments.
More Related Videos
Related Concept Videos
Absorption of Radiation
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Mechanisms of Heat Transfer II
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...