Heart rate variability enhances the accuracy of non-invasive continuous blood pressure estimation under blood loss
Guang Zhang1, Zongge Wang1, Feixiang Hou1
1Institute of Medical Support, Academy of Military Sciences, Tianjin 300161, China.
Abstract:
To propose a new method for real-time monitoring of blood pressure of blood loss (BPBL), this article combines pulse transit time (PTT) and heart rate variability (HRV) as input parameters to build a model for BPBL estimation. In this article, effective parameters such as PTT, R-R interval (RRI), and HRV were extracted and used to establish the blood pressure (BP) estimation. Three BP estimation models were created: the PTT model, the RRI model, and the HRV model, and they were divided into an experimental group and a control group. Finally, the effects of the different estimation models on the accuracy of BPBL were evaluated using the experimental results. The result showed that both the RRI model and the HRV model have a good improvement effect on the prediction accuracy of BPBL, and the HRV model has the highest prediction accuracy than the PTT model and the RRI model. The correlation coefficients between the actual systolic BP (SBP) and diastolic BP (DBP) and the estimated SBP and DBP of the HRV model were 0.9580 and 0.9749, respectively, and the root-mean-square error of the HRV model for both SBP and DBP were 7.59 and 6.56 mmHg, respectively. The results suggest that the accuracy of the BPBL estimated by the HRV models is better than that of the PTT model, which means that HRV seems to be more effective in improving the accuracy of BP estimation compared with RRI. These results in this article provide a new idea for other researchers in the field of BPBL estimation research.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)