Related Experiment Video
Updated: Oct 15, 2025

How to Ignite an Atmospheric Pressure Microwave Plasma Torch without Any Additional Igniters
Published on: April 16, 2015
Nonlinear transmission line implemented as a combined pulse forming line and high-power microwave source
Andrew J Fairbanks1, Travis D Crawford1, Allen L Garner1
1School of Nuclear Engineering, Purdue University, West Lafayette, Indiana 47906, USA.
Abstract:
Nonlinear transmission lines (NLTLs) are typically driven by pulse forming lines (PFLs) or Marx generators to generate high repetition rate, high power microwaves (HPMs) with fewer auxiliary systems than conventional sources. This paper reports the development of an even more compact HPM system that utilizes a composite-based hybrid NLTL as the PFL and HPM generator in a single device. We designed the following three different combinations of nickel zinc ferrite (NZF) and barium strontium titanate (BST) inclusion volume loads in a polydimethylsiloxane host material to provide magnetic field dependent permeability and electric field dependent permittivity, respectively: 25% NZF, 10% BST/15% NZF, and 15% BST/10% NZF. By constructing the NLTL in a coaxial geometry, this device uses the capacitance and length of the NLTL to generate a fast rise-time high voltage pulse with microwave oscillations that occurred both during and after the pulse after exceeding a threshold charging voltage. The output frequency of the NLTLs ranged from 950 MHz to 2.2 GHz during the pulse for all volume loadings and was 1 GHz after the pulse for the 10% BST/15% NZF and 15% BST/10% NZF volume loadings. The oscillations generated after the pulse were much higher in amplitude and achieved 160 kW at a 15 kV charging voltage for the 15% BST/10% NZF composite-based NLTL.
Related Concept Videos
Transmission Line Design Considerations
Lossless Lines
Lossy Lines and Overvoltages
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Maximum Power Flow and Line Loadability
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...