A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery
Cheng-Chih Hsieh1,2,3, An-Bang Zeng1,3, Chia-Hung Chen1,2,3
1Department of Radiology, MacKay Memorial Hospital, No.92, Sec.2, Zhongshan North Rd., Taipei, 10449, Taiwan.
Background:
Enhancement profiles of the pulmonary artery (PA) and aorta differ when using computed tomography (CT) angiography. Our aim was to determine the optimal CT protocol for a one-time CT scan that assesses both blood vessels.
Methods:
We prospectively enrolled 101 cases of CT angiography in patients with suspected pulmonary embolism or aortic dissection from our center between 2018 and 2020. We also retrospectively collected the data of 40 patients who underwent traditional two-time CT scans between 2015 and 2018. Patients were divided into four groups: test bolus (TB) I, TB II, bolus-tracking (BT) I, and BT II. The enhancement of the PA and aorta, and the radiation doses used in the four groups were collected. Those who underwent two-time scans were classified into the traditional PA or aorta scan groups. Data were compared between the BT and traditional groups.
Results:
The aortic enhancement was highest in BT II (294.78 ± 64.48 HU) followed BT I (285.18 ± 64.99 HU), TB II (186.58 ± 57.53 HU), and TB I (173.62 ± 69.70 HU). The radiation dose used was lowest in BT I (11.85 ± 5.55 mSv) and BT II (9.07 ± 3.44 mSv) compared with that used in the traditional groups (20.07 ± 7.78 mSv) and accounted for half of the traditional group (45.17-59.02%). The aortic enhancement was also highest in BT II (294.78 ± 64.48 HU) followed by BT I (285.18 ± 64.99 HU) when compared with that in the traditional aorta scan group (234.95 ± 94.18 HU).
Conclusion:
Our CT protocol with a BT technique allows for a lower radiation dose and better image quality of the PA and aorta than those obtained using traditional CT scans.
Trial Registration:
NCT04832633, retrospectively registered in April 2021 to the clinical trial registry.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Radiological Investigation I: X-ray and CT