Comparison of the Analysis of Respirable Crystalline Silica in Workplace Air by Direct-on-Filter Methods using X-ray
Akemi Ichikawa1, John Volpato1, Gregory E O'Donnell1
1Chemical Analysis Branch, TestSafe Australia-SafeWork NSW, Thornleigh, NSW, Australia.
Abstract:
A comparison of the analysis of respirable crystalline silica direct-on-filter methods using X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy was undertaken using 253 real workplace air samples from road construction and tunnelling, coal mining, and kitchen benchtop manufacturing in Australia. Using pure α-quartz standards, XRD and FT-IR direct-on-filter analyses produced identical test results, however, the real workplace samples showed a clear discrepancy between FT-IR and XRD results with on average a 9% positive bias of the FT-IR results. The cause of the positive bias was due to matrix interferences which was confirmed by using synthetic mixture air samples. Approximately a third of the data by direct-on-filter method using FT-IR was assessed to be invalid based on the peak height ratio criterion due to excessive interferences and weight overload limitations. The XRD method showed better results due to less interference from the common matrices. XRD could handle up to twice the sample loading and at higher loadings up to 7 mg when a correction was applied. It was also able to achieve a lower limit of detection of 2 µg filter-1 when a slower scan condition was utilized.
More Related Videos
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
10:31Diffuse Reflectance Infrared Spectroscopic Identification of Dispersant/Particle Bonding Mechanisms in Functional Inks
Published on: May 8, 2015
Related Concept Videos
IR Spectrometers
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Applications of IR Spectroscopy: Overview
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...