Related Concept Videos
Circuit Breaker and Fuse Selection
189
A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...
In high-voltage systems,...
189
Switching of BJT
529
Switching behavior in Bipolar Junction Transistors (BJTs) is a fundamental aspect utilized in various electronic circuits, particularly for digital logic applications like switches and amplifiers. In a typical switching circuit, a BJT alternates between cut-off and saturation modes, corresponding to the "off" and "on" states, respectively, thus behaving like an ideal switch.
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
529
Reclosers and Fuses
182
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
182
Overcurrent Relays
178
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
178
Power System Three-Phase Short Circuits
173
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
173
Restarting Stalled Replication Forks
6.0K
DNA replication is initiated at sites containing predefined DNA sequences known as origins of replication. DNA is unwound at these sites by the minichromosome maintenance (MCM) helicase and other factors such as Cdc45 and the associated GINS complex.The unwound single strands are protected by replication protein A (RPA) until DNA polymerase starts synthesizing DNA at the 5’ end of the strand in the same direction as the replication fork. To prevent the replication fork from falling apart,...