Related Experiment Video
Updated: Oct 15, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Chemical Degradation of Intravenous Chemotherapy Agents and Opioids by a Novel Instrument
Mark Macdonell1, Jitesh D Kawedia2, Yan Ping Zhang2
1Clear River Enviro, Inc., Sugar Land, TX, USA.
Abstract:
Purpose: To assess chemical degradation of various liquid chemotherapy and opioid drugs in the novel RxDestruct™ instrument. Methods: Intravenous (IV) drug solutions for chemotherapy and pain management were prepared using 0.9% normal saline in Excel® bags to a final volume of 500 mL. We investigated duplicate IV solutions of methotrexate (0.1 mg/mL), etoposide (0.4 mg/mL), doxorubicin (0.25 mg/mL), cladribine (12.4 µg/mL), fentanyl (1.0 µg/mL), and hydromorphone (12.0 µg/mL) in this study. Solutions were poured into an automated instrument to undergo pulsatile chemical treatment (Fenton reactions) for 20 minutes, and then discharged from the instrument through a waste outlet. Extent of intact drug degradation was determined by measuring concentrations of drugs before entry into the instrument and after chemical treatment in the filtrate using high-performance liquid-chromatography with ultraviolet detection (HPLC-UV). Results: Following chemical reactions (Fenton processes) in the automated instrument, infusion solutions containing methotrexate, etoposide, doxorubicin, and cladribine had levels below the HPLC-UV limit of quantification (LOQ), indicating <50 ppb of each. This equated to >99.5%, 99.99%, 99.9%, and 99.8% intact drug loss, respectively. Likewise, processed samples of fentanyl and hydromorphone contained levels below the LOQ (78 and 98 ng/mL, respectively), indicating extensive degradation (>92.2% and 99.2% intact drug loss, respectively). Conclusion: The novel instrument was capable of degrading intact chemotherapy and opioid drugs prepared in infusion solutions to undetectable quantities by HPLC-UV. RxDestruct™ is a possible alternative for disposal of aqueous medication waste.
More Related Videos
08:57Sample Extraction and Simultaneous Chromatographic Quantitation of Doxorubicin and Mitomycin C Following Drug Combination Delivery in Nanoparticles to Tumor-bearing Mice
Published on: October 5, 2017
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
Related Concept Videos
Enhanced Elimination of Poison
Antidotes serve a crucial role in counteracting the effects of poison by inhibiting enzymes responsible for producing harmful drug metabolites. In some cases, these toxic metabolites can be neutralized by endogenous cosubstrates, which are maintained at specific concentrations to prevent interaction with cellular macromolecules and subsequent cell death.
Renal excretion is the...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
In Vitro Drug Dissolution: Alternative Methods
Prevention of Further Absorption of Poison
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis