Related Experiment Video
Updated: Oct 14, 2025

Measurements of Local Instantaneous Convective Heat Transfer in a Pipe - Single and Two-phase Flow
Published on: April 30, 2018
Direct velocity measurements in high-temperature non-ideal vapor flows
Simone Gallarini1, Fabio Cozzi1, Andrea Spinelli1
1Energy Department, Politecnico di Milano, Milano, Italy via Lambruschini, 4A, 20156.
Abstract:
Direct velocity measurements in a non-ideal expanding flow of a high temperature organic vapor were performed for the first time using the laser Doppler velocimetry technique. To this purpose, a novel seeding system for insemination of high-temperature vapors was specifically conceived, designed, and implemented. Comparisons with indirectly measured velocity, namely inferred from pressure and temperature measurements, are also provided. Nozzle flows of hexamethyldisiloxane (MM, C H OSi ) at temperature up to and pressure up to 10 bar were taken as representative of non-ideal compressible-fluid flows. The relative high temperature, high pressure and the need of avoiding contamination pose strong constraints on the choice of both seeding system design and tracer particle, which is solid. A liquid suspension of tracer particles in hexamethyldisiloxane is injected through an atomizing nozzle in a high-temperature settling chamber ahead of the test section. The spray droplets evaporate, while the particles are entrained in the flow to be traced. Three different test cases are presented: a subsonic compressible nozzle flow with a large uniform region at Mach number 0.7, a high velocity gradient supersonic flow at Mach number 1.4 and a near-zero velocity gradient flow at Mach number 1.7. Temperature, pressure and direct velocity measurements are performed to characterize the flow. Measured velocity is compared with both computational fluid dynamics (CFD) calculations and velocity computed from pressure and temperature measurements. In both cases, the thermodynamic model applied was a state-of-the-art Helmoltz energy equation of state. A maximum velocity deviation of 6.6% was found for both CFD simulations and computed velocity.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Vapor Pressure of Fluid
When a liquid is placed in a closed container with a small air space, and the space is evacuated, vapor molecules will...
Pipe Flowrate Measurement: Problem Solving
Velocity and Acceleration in Steady and Unsteady Flow
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over...
Steady, Laminar Flow in Circular Tubes
Distribution of Molecular Speeds

