Related Experiment Video
Updated: Oct 14, 2025

Author Spotlight: Expanding Interventional Pulmonology Research with Robotic-Assisted Bronchoscopy
Published on: July 19, 2024
The PEARL Approach for CT-guided Lung Biopsy: Assessment of Complication Rate
Arash Najafi1, Marc Al Ahmar1, Baptiste Bonnet1
1From the Department of Interventional Radiology, Institut Gustave Roussy, Villejuif, Île-de France, France.
Abstract:
Background Percutaneous CT-guided biopsy of lung nodules is an established method with high diagnostic accuracy but a high rate of pneumothorax and chest tube insertion compared with endobronchial methods. Purpose To investigate the effect of a protocol combining patient positioning biopsy-side down, needle removal during expiration, autologous blood patch sealing, rapid rollover, and pleural patching (PEARL) on complication rate after percutaneous CT-guided lung biopsy, especially chest tube insertion. Materials and Methods In a secondary analysis of both prospectively and retrospectively acquired data from December 2019 to November 2020, consecutive participants underwent biopsy with use of the PEARL protocol (prospective data) and were compared with patients who underwent biopsy at the same tertiary cancer center according to the standard method without any additional techniques (controls, retrospective data). Patient demographics, lesion characteristics, intraprocedural data, complications, and histologic results were recorded and compared. Results One hundred patients in the control group (mean age ± standard deviation, 63 years ± 12; 61 men) and 100 participants in the PEARL group (mean age, 64 years ± 12; 48 men) were evaluated. No differences were found in patient and lesion characteristics. The emphysema rate was 47 of 100 patients (47%) in both groups. The rate of pneumothorax was 37 of 100 patients (37%) in the control group versus 16 of 100 (16%) in the PEARL group (P = .001). Of the pneumothoraxes that occurred, fewer were during the intervention in the PEARL group, with 21 of 37 onsets (57%) in the control group versus three of 16 onsets (19%) in the PEARL group (P < .001). A chest tube was inserted in 13 of 100 patients (13%) in the control group and only in one of 100 (1%) in the PEARL group (P = .002). Histologic findings were diagnostic in 94 of 100 patients (94%) in the control group and 95 of 100 (95%) in the PEARL group (P > .99). Conclusion During CT-guided percutaneous lung biopsy, a protocol of positioning biopsy-side down, needle removal during expiration, autologous blood patch sealing, rapid rollover, and pleural patching, or PEARL, reduced rates of pneumothorax and chest tube insertion. © RSNA, 2021.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
06:03Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules
Published on: May 23, 2015