Related Experiment Video
Updated: Oct 14, 2025

A Novel Application of Musculoskeletal Ultrasound Imaging
Published on: September 17, 2013
Validity and reliability of linear position transducers and linear velocity transducers: a systematic review
Adrián Moreno-Villanueva1, José Pino-Ortega1,2, Markel Rico-González2,3
1Faculty of Sports Sciences, University of Murcia, San Javier, Spain.
Abstract:
This systematic review aimed to summarise and analyse the evidence on the reliability and validity of linear tranducers (LTs) in exercises of different nature and different modes of execution. This systematic review was carried out under PRISMA guidelines, and was carried out using three databases (PubMed, Web of Sciences, and Scopus). Of the 351 initially found, 21 were included in the qualitative synthesis. The results reflected that linear position transducers (LPTs) were valid and reliable in monitoring movement velocity in non-plyometric exercises. However, precision and reliability were lower in execution protocols without isometric phase and in the execution of exercises in multiple planes of movement, with greater measurement errors at higher sampling frequencies. On the other hand, linear velocity transducers (LVTs) proved to be valid and reliable in measuring velocity during plyometric and non-plyometric exercises performed on the Smith machine, with less variation in measurement in the latter. Finally, the use of peak values is recommended, since they are less dependent on the technological errors of LTs. Therefore, the performance of non-plyometric exercises, carried out in the Smith machine and with an isometric phase in the execution of the movement, will help to minimise the technological error of the LTs.
Related Concept Videos
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Relating Angular And Linear Quantities - I
When comparing the linear and rotational variables individually, the linear variable of position has physical units of meters, whereas the angular position variable has dimensionless units of radians, as it is the ratio of two lengths. The linear velocity...
Relative Motion Analysis - Acceleration
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...