Performance of ion pairing chromatography and hydrophilic interaction liquid chromatography coupled to charged
Ruben Pawellek1, Ulrike Holzgrabe1
1University of Würzburg, Institute for Pharmacy and Food Chemistry, 97074 Würzburg, Germany.
Abstract:
The charged aerosol detector (CAD) is frequently employed in liquid chromatography for the analysis of small polar and ionizable compounds such as amino acids and amino sugars, which provide a weak chromophore only. Separation of these compounds is achieved by means of ion pair chromatography (IPC), and, more recently, hydrophilic interaction chromatography (HILIC) techniques. However, as the CAD's response is highly dependent on the mobile phase composition, the substantial differences in the mobile phase composition of IPC and HILIC have a distinct impact on the detector's performance. This study was aimed at systematically comparing the performance of IPC and HILIC when coupled to the CAD. Therefore, the separation techniques characterized by their specific mobile phase compositions were evaluated for their influence on the CAD response and the signal-to-noise ratio (S/N) of the amino acids L-alanine, L-leucine, and L-phenylalanine applying the response surface methodology (RSM). The RSM results derived from flow injection analysis (FIA) indicated that the CAD response and thus the obtainable S/N are significantly higher in HILIC compared to IPC where the S/N decreased with the chain length of the applied ion-pairing reagent. In addition, an IPC and a HILIC method, respectively, were developed for the impurity profiling of the branched-chain amino acids (BCAAs) L-leucine, L-isoleucine, and L-valine. The beneficial effects of the HILIC conditions on the S/N observed under FIA conditions were partly offset by moderate column bleed effects when using an amide functionalized column, which facilitates the separation in the HILIC method. Satisfactory LOQs (3-10 ng on column) were obtained with both methods; however, the HILIC method was found to be slightly superior in terms of sensitivity and separation efficiency.
More Related Videos
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Affinity Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: