A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Evaluation of a novel endotracheal tube suctioning system incorporating an inflatable sweeper
John D Davies1, Yuh Chin Huang1, Neil R MacIntyre1
1Division of Pulmonary and Critical Care Medicine, Duke University Medical Center, Durham, NC, USA.
Introduction:
Accumulation of secretions in an endotracheal tube can increase the resistance to flow resulting in an increased patient work of breathing when the patient is interacting with the ventilator. Retained secretions can also serve as an infection risk. Standard suction catheters are limited in their ability to keep the lumen of the endotracheal tube clear. A novel closed-suction catheter has been introduced that incorporates a balloon at its distal end that, when inflated, physically scrapes secretions out of the endotracheal tube (CleanSweep catheter (CSC), Teleflex, Morrisville NC). We hypothesized that the CSC would be more efficient at removing secretions from inside the endotracheal tube than a standard suction catheter (SSC).
Methods:
We performed a bench study examining resistive pressures across different sizes of endotracheal tubes when cleaned by the CSC as compared with an SSC. This study was followed by a prospective crossover study again comparing the CSC with an SSC in intubated intensive care unit patients receiving mechanical ventilation and requiring frequent suctioning.
Results:
For the bench study the CSC was significantly better in reducing airway resistive pressures (P < 0.001). In the prospective crossover study the CSC over 2 h also removed significantly more secretions than the SSC (P < 0.05).
Conclusion:
Both our bench and crossover clinical study demonstrated improved clearance of secretions with the CSC vs an SSC. Further research is needed to ascertain the clinical outcome benefits of enhanced secretion removal.
More Related Videos
06:19Author Spotlight: Implications of Non-Nutritive Sucking on Speech Emergence and Infant Development
Published on: April 19, 2024
08:57VacuSIP, an Improved InEx Method for In Situ Measurement of Particulate and Dissolved Compounds Processed by Active Suspension Feeders
Published on: August 3, 2016
Related Concept Videos
Tracheostomy Suctioning II: Procedure
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....