Related Experiment Video
Updated: Oct 14, 2025

Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students
Published on: June 16, 2018
Continuous Stress Detection of Hospital Staff Using Smartwatch Sensors and Classifier Ensemble
Muhammad Ali Fauzi1, Bian Yang1
1Norwegian University of Science and Technology, Gjøvik, Norway.
Abstract:
High stress levels among hospital workers could be harmful to both workers and the institution. Enabling the workers to monitor their stress level has many advantages. Knowing their own stress level can help them to stay aware and feel more in control of their response to situations and know when it is time to relax or take some actions to treat it properly. This monitoring task can be enabled by using wearable devices to measure physiological responses related to stress. In this work, we propose a smartwatch sensors based continuous stress detection method using some individual classifiers and classifier ensembles. The experiment results show that all of the classifiers work quite well to detect stress with an accuracy of more than 70%. The results also show that the ensemble method obtained higher accuracy and F1-measure compared to all of the individual classifiers. The best accuracy was obtained by the ensemble with soft voting strategy (ES) with 87.10% while the hard voting strategy (EH) achieved the best F1-measure with 77.45%.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...