Exploring medical device-related pressure injuries in a single intensive care setting: A longitudinal point
Fiona Coyer1, Jane-Louise Cook2, Anna Doubrovsky2
1Joint Appointment Intensive Care Services, Royal Brisbane and Women's Hospital and School of Nursing, Queensland University of Technology, Australia; Institute of Skin Integrity and Infection Prevention, University of Huddersfield, UK; Level 3 Ned Hanlon Building, Royal Brisbane and Women's Hospital, Butterfield St, Herston, Queensland 4029, Australia.
Objectives:
To report longitudinal prevalence rates of device-related pressure injuries in critically ill adult patients in the intensive care unit and to explore the patient characteristics associated with the development of device related pressure injuries.
Research Design:
A prospective observational design where observations of patients' skin integrity were conducted on one day each week for 52 weeks.
Setting:
The study was conducted in the 36-bed intensive care unit of a major metropolitan tertiary referral hospital in Queensland, Australia. The sample included all patients aged 18 years or older admitted to the intensive care unit before midnight on the day preceding the observation, with a medical device in situ.
Main Outcome Measures:
The primary outcome measure was device related pressure injuries identified at the weekly observations and defined as a pressure injury found on the skin or mucous membrane with a history of medical device in use at the location of the injury. Patient demographic and clinical characteristics were recorded.
Results:
Over the study period, 11.3% (71/631) of patients developed at least one hospital-acquired DRPI. The most common devices associated with injury were nasogastric/nasojejunal tubes (41%) and endotracheal tubes (27%). Significant predictors of device related pressure injuries were the total number of devices (OR 1.230, 95% CI 1.09-1.38, p < 0.001), the length of time in the ICU (OR 1.05, 95% CI 1.02-1.09, p = 0.003), male sex, (OR 2.099, 95% CI 1.18-3.7, p = 0.012), and increased severity of illness score on admission (OR 1.044, 95% CI 1.01-1.09, p = 0.013).
Conclusion:
Device related pressure injuries are an all-too-common iatrogenic problem for this vulnerable patient cohort.
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Endocarditis IV: Nursing Management
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.