Ultra-high b value DWI in distinguishing fresh gray matter ischemic lesions from white matter ones: a comparative

Xinming Huang1, Xue Xu1, Yifan Sun1

  • 1Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.

Abstract

Insights

Ultra-high b value diffusion-weighted imaging (DWI) effectively distinguishes fresh ischemic lesions (FILs) in gray matter (GM) and white matter (WM). Higher b values show increased sensitivity in differentiating these lesion types.

Area of Science:

  • Neurology
  • Radiology
  • Medical Imaging

Background:

  • Fresh ischemic lesions (FILs) in gray matter (GM) and white matter (WM) have different prognoses.
  • Distinguishing FILs in GM vs. WM is crucial for patient outcomes.

Purpose of the Study:

  • To evaluate ultra-high b value diffusion-weighted imaging (DWI) for differentiating FILs in GM and WM.
  • To compare its efficacy against routine and high b value DWI.

Main Methods:

  • Performed multi-b value DWI (up to 10,000 s/mm²) on 47 patients with suspected acute ischemic stroke (AIS).
  • Calculated apparent diffusion coefficient (ADC) maps and compared mean ADC values between GM and WM FILs.
  • Utilized Mann-Whitney U tests and receiver operating characteristic (ROC) curves for analysis.

Main Results:

  • Significantly lower ADC values were observed in WM FILs compared to GM FILs at b values of 2,000 s/mm² and higher (P<0.001).
  • No significant differences were found at b values of 500 and 1,000 s/mm².
  • Area under the curve (AUC) in ROC analysis increased with b value, reaching 0.872 at 10,000 s/mm².

Conclusions:

  • Ultra-high b value DWI demonstrates high sensitivity in detecting diffusion differences between GM and WM FILs.
  • Increasing b values enhance the ability to differentiate lesion microenvironments.
  • This technique offers clinical advantages for identifying FIL microstructure.