When your MR linac is down: Can an automated pipeline bail you out of trouble?
L Placidi1, D Cusumano2, A Alparone3
1Fondazione Policlinico Universitario ''A. Gemelli'' IRCCS, Rome, Italy; Università Cattolica del Sacro Cuore, Rome, Italy.
Purpose:
The unique treatment delivery technique provided by magnetic resonance guided radiotherapy (MRgRT) can represent a significant drawback when system fail occurs. This retrospective study proposes and evaluates a pipeline to completely automate the workflow necessary to shift a MRgRT treatment to a traditional radiotherapy linac.
Material And Methods:
Patients undergoing treatment during the last MRgRT system failure were retrospectively included in this study. The core of the proposed pipeline was based on a tool able to mimic the original MR linac dose distribution. The so obtained dose distribution (AUTO) has been compared with the distribution obtained in the conventional radiotherapy linac (MAN). Plan comparison has been performed in terms of time required to obtain the final dose distribution, DVH parameters, dosimetric indices and visual analogue scales scoring by radiation oncologists.
Results:
AUTO plans generation has been obtained within 10 min for all the considered cases. All AUTO plans were found to be within clinical tolerance, showing a mean target coverage variation of 1.7% with a maximum value of 4.3% and a minimum of 0.6% when compared with MAN plans. The highest OARs mean variation has been found for rectum V60 (6.7%). Dosimetric indices showed no relevant differences, with smaller gradient measure in favour of AUTO plans. Visual analogue scales scoring has confirmed comparable plan quality for AUTO plans.
Conclusion:
The proposed workflow allows a fast and accurate generation of automatic treatment plans. AUTO plans can be considered equivalent to MAN ones, with limited clinical impact in the worst-case scenario.
More Related Videos
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Distribution Reliability and Automation
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...