Related Experiment Video
Updated: Oct 14, 2025

Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
The effect of flow partition on storm runoff and pollutant retention through raingardens with and without subsurface
Qing Xu1, Zhonghua Jia1, Shuangcheng Tang1
1College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou, 225009, Jiangsu, China.
Abstract:
Green infrastructures (GIs) have been advocated worldwide to mitigate the negative impact of urbanization on regional hydrological cycle, their functions are closely related to their design features and the local environmental condition. This paper reports a field monitoring study that aimed to investigate how runoff partition in raingardens would affect flow and pollutant retention. A paired field experiment was conducted to compare runoff and pollutant retentions in two raingardens with and without subsurface drainage in a shallow water table area. Concentrations of ammonia nitrogen (NH3-N), nitrate nitrogen (NO3-N) and total phosphorus (TP) were measured at raingarden inflow, overflow and drainage paths. The results from 28 monitored storm events over two years showed that the raingarden without subsurface drainage achieved its retention mainly through ponding and infiltration, its pollutant retention rates (76% for TP, 81% for NO3-N, and 79% for NH3-N) were higher than its runoff retention rate (61%), indicating a first flush effect on pollutants retention in the raingarden during storm events, especially when the raingarden was empty and dry. The raingarden with subsurface drainage facilitated quick discharge of water, the observed runoff reduction through the raingarden was 36%; pollutant removal rates were quite variable: NH3-N was removed by 91% while the NO3-N and TP were increased by 3-47%. These results suggest that facilitating specific processes for targeted pollutants is necessary for achieving substantial pollutant removal in a stormwater retention device. Subsurface drainage pipes resulted in short circulating of runoff and lowered pollutant removal rates in the raingarden. Considering the water table fluctuation during the experimental period, we recommend to build infiltration-based GI devices to better capture first flush in intensively developed urban area, which caused deeper groundwater table. In conclusion, installations of different GI devices in urban landscape need to consider the local environmental conditions and facilitate the design features to meet specific storm runoff and pollutants mitigation requirement.
Related Concept Videos
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
Gradually Varying Flow
Underflow Gates
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Rapidly Varying Flow
Laminar Flow