Validation of the pediatric Radboud Dysarthria Assessment
Marieke Ruessink1, Lenie van den Engel-Hoek2, Marjo van Gerven2
1Sint Maartenskliniek, Department of Rehabilitation, Nijmegen, The Netherlands.
Purpose:
The Radboud Dysarthria Assessment (RDA) was published in 2014. Adaptation into a pediatric version (p-RDA) was required because of relevant differences between children and adults. The purpose of this study was to assess the feasibility of the p-RDA and to test intra-rater and inter-rater reliability as well as the validity of the two severity scales (function and activity level).
Methods:
Video recordings were made of 35 participants with (suspected) dysarthria (age 4 to 17 years) while being assessed using the p-RDA. Intra-rater reliability was assessed by one, and inter-rater reliability by two experiments using the Intraclass Correlation Coefficient (ICC). Validity of the severity scales was tested by correlating the consensus scores with the independently rated scores on four communication scales, three mobility scales, and one self-care scale using Spearman correlation coefficients (rs).
Results:
The assessment was applicable for 89% of the tested sample, with good intra-rater and inter-rater reliability (ICC = 0.88-0.98 and 0.83-0.93). The p-RDA severity scales (function and activity level) correlated from substantially to strongly with the communication scales (rs = 0.69-0.82 and 0.77-0.92) and self-care scale (rs = 0.76-0.71) and correlated substantially with the mobility scales (rs = 0.49-0.60).
Conclusion:
The feasibility, reliability and validity of the p-RDA are sufficient for clinical use.
More Related Videos
09:00Author Spotlight: Validation of SICOLE-R for Assessing Cognitive and Reading Skills in Spanish-Speaking Children and Its Role in Personalized Education
Published on: August 16, 2024
09:16Use of a Video Scoring Anchor for Rapid Serial Assessment of Social Communication in Toddlers
Published on: March 14, 2018
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
