High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Rethinking Drug Analysis in Health Care: High-Throughput Analysis of 71 Drugs of Abuse in Oral Fluid Using Ion
Moa Andresen Bergström1,2, Hanna Lövgren1, Anna Abrahamsson1
1Laboratory of Clinical Chemistry, Sahlgrenska University Hospital, Bruna Stråket 16, Gothenburg 413 45, Sweden.
Abstract:
We have identified a clinical need for a sensitive, specific, flexible, comprehensive and affordable analytical technology to efficiently detect polydrug use. In addition, the current standard practice of surveilled urine sampling is uncomfortable for the patient; hence, more patient-friendly sample collection methods are requested. To fill these needs, we have developed and validated a high-throughput liquid chromatography-high-resolution mass spectrometry (LC--HRMS) method for the analysis of drugs of abuse (DoA) in oral fluid (OF). The method covers a panel of 71 substances including traditional DoA, prescription narcotics and new psychoactive substances (NPS), with a guaranteed limit of identification of <3 µg/L for 87% of the analytes. Method validation showed high accuracy (>99.7%), sensitivity (>99.7%) and specificity (100%). Most analytes had a high process efficiency during the salting-out liquid-liquid extraction sample preparation and no or only a minor matrix effect during the analysis. We have implemented this method in clinical routine and present data from 18,579 OF samples collected during routine patient treatment in mainly psychiatric and addiction clinics in West Sweden between September 2020 and June 2021. Seventy-one percent of the samples were positive and a total of 41,472 DoA findings were detected. Amphetamine (27%), buprenorphine (25%), nordiazepam (18%) and alprazolam (16%) were most prevalent. New psychoactive substances were detected in 189 samples (1.0%). The occurrence of polydrug use was common; 34% of the positive samples contained three analytes or more and 12% six or more. To the best of our knowledge, this is the first method for comprehensive analysis of DoA in OF using LC--HRMS and the largest dataset published on the detection of DoA in OF. With the current complex and variable drug use pattern, this broad, cost-effective and reliable method has largely replaced immunoassay screening in urine in our laboratory.
More Related Videos
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
Mass Analyzers: Common Types
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...