Related Experiment Video
Updated: Oct 14, 2025

Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization
Published on: March 3, 2023
Wider is better but sharper is not: optimizing the image of camera-monitor systems
Christoph Bernhard1, Aljoscha Klem1, Elias C Altuntas1
1Experimental Psychology, Johannes Gutenberg-Universität Mainz, Mainz, Germany.
Abstract:
The replacement of rear-view mirrors with camera-monitor systems introduces new opportunities for design, such as altering the image quality and the rearward field-of-view. We investigated how the image quality and field-of-view might affect the distance and time-to-contact estimation of other vehicles. Eighty-six subjects estimated either their egocentric distance to a stationary vehicle (Experiment I) or the time-to-contact to an approaching vehicle (Experiment II). Throughout the experiments, the pixel density and either the field-of-view or the viewing condition varied. A larger field-of-view increased distance estimation accuracy and confidence. Reduced pixel density led to larger estimates. In contrast, reduced pixel density and simulated dirt shortened time-to-contact estimates. This is compatible with a safety strategy applied under conditions of impaired vision. Moreover, a limited benefit was observed for higher pixel densities. Therefore, camera-monitor systems with large field-of-view and a pixel density of around 300 ppi could ensure accurate TTC and distance estimation. Practitioner summary: A camera's field-of-view and image quality are important parameters for camera-monitor systems. In two experiments, we investigated the effects of these two parameters on rearward distance and time-to-contact estimation. Whereas a larger field-of-view improved distance estimation accuracy, increasing the pixel density had a limited effect in the estimation of time-to-contact.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Focusing of Light in the Eye
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Super-resolution Fluorescence Microscopy

