Pulse Taking by a Piezoelectric Film Sensor via Mode Energy Ratio Analysis Helps Identify Pregnancy Status

In order to solve the problem of non-invasive diagnosis and monitoring of women during pregnancy, a piezoelectric film pulse sensing system combined with the mode energy ratio (MER) analysis is utilized to detect human pulses to reveal pregnant conditions. Inspired by traditional Chinese medicine (TCM), pulse diagnosis has a history of more than 2,500 years. The life energy of the human body helps the diagnosis of the disease through the circulation of blood vessels connected to the organs. A PVDF piezoelectric film sensor is used to emulate the pulse taking process in TCM to record the pulse signals. And the algorithm of MER is proposed based on empirical mode decomposition (EMD). Through the MER analysis of 83 female volunteers with different pregnancy statuses, the identification and warning of pregnancy status and physical health indicators are realized.

Related Concept Videos

Pulse rhythm01:30

Pulse rhythm

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
988
Special considerations while measuring pulse01:13

Special considerations while measuring pulse

Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
675
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.8K
Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
916