Related Experiment Video
Updated: Oct 14, 2025

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
Wrist-based accelerometer cut-points for quantifying moderate-to-vigorous intensity physical activity in Parkinson's
Brenda Jeng1, Katie L J Cederberg2, Byron Lai3
1Department of Physical Therapy, University of Alabama at Birmingham School of Health Professions, 360, 1720 2nd Ave S, Birmingham, AL 35233, United States.
Researchers developed a new method to measure physical activity in people with Parkinson's disease (PD). Wrist-worn accelerometers provide a more accurate way to track moderate-to-vigorous physical activity (MVPA) for individuals with PD.
Area of Science:
- Biomedical Engineering
- Movement Science
- Neurology
Background:
- Parkinson's disease (PD) is associated with low physical activity levels.
- Current methods for measuring moderate-to-vigorous physical activity (MVPA) using accelerometers may not be accurate for individuals with PD when using wrist-worn devices.
- Wrist-worn devices offer potential for improved accessibility and compliance in monitoring physical activity for PD patients.
Purpose of the Study:
- To investigate the relationship between wrist-based activity counts and energy expenditure during treadmill walking in individuals with PD.
- To determine if cut-points for quantifying MVPA differ between individuals with PD and age- and sex-matched controls.
Main Methods:
- 26 individuals with mild-to-moderate PD and 27 matched controls participated.
- Participants completed treadmill walking at varying speeds while wearing wrist-worn ActiGraph GT3X+ accelerometers.
- Energy expenditure was measured using portable open-circuit spirometry.
Main Results:
- A strong association was found between activity counts and energy expenditure in both groups (R² ≈ 0.94-0.95).
- The cut-point for MVPA in individuals with PD was significantly lower (2883 counts·min⁻¹) compared to controls (4389 counts·min⁻¹).
Conclusions:
- A specific cut-point for wrist-worn accelerometers was established for individuals with PD.
- This PD-specific cut-point may enhance the accuracy of measuring MVPA in this population.
Related Concept Videos
Parkinson's Disease: Overview
Parkinson's Disease: Treatment
Parkinson's Disease is primarily a result of the loss of dopaminergic neurons in the substantia nigra pars compacta. The cornerstone of...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

