A quantitative comparison between using sodium hypochlorite as a digestion method for the diatom test and the
Shigeki Tsuneya1, Makoto Nakajima2, Yohsuke Makino1
1Department of Forensic Medicine, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan; Department of Legal Medicine, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670, Japan.
Objective:
To determine the efficacy of using sodium hypochlorite (NaClO, Purelox) as a simple and rapid alternative digestion method for the diatom test through a quantitative comparison with the conventional method that uses fuming nitric acid (HNO3).
Materials And Methods:
In experiment 1, using 30 water samples, the NaClO and HNO3 methods were compared using paired t-test. In experiments 2 and 3, we included blank human lung plus 13 water samples and total of 32 drowned human lung samples, respectively, to compare the NaClO and HNO3 methods using paired t-test. The relationship between the concentration ratio and background factors was tested in experiment 3. Welch's t-test was used to determine differences in the ratio between the lung side and sex, whereas Pearson's correlation coefficient was used to determine the correlation between the ratio and either age or postmortem interval. The geometric mean of two counts was used for each specimen and all counts were logarithmically transformed to base 2 in the statistical analysis.
Results:
The NaClO method was completed within 80 min for any sample. In experiment 1, there was no significant difference between the NaClO and HNO3 methods using water samples (the mean of the ratios: 0.99, 95% confidence interval (95%CI: 0.89-1.10, P = 0.80). In experiment 2, the count of the NaClO method was lower than that of the HNO3 method using lung plus water samples (the mean of the ratios: 0.47, 95% CI: 0.35-0.65, P = 0.0002). In experiment 3, the concentration of the NaClO method was lower than that of the HNO3 method using drowned lung samples (the mean of the ratios: 0.28, 95% CI: 0.20-0.38, P < 0.0001). A weak correlation between the postmortem interval and the ratio of the two methods was observed (r = -0.58, P = 0.012), although no difference between lung sides or sexes were detected (P = 0.87 and P = 0.50, respectively) and no correlation occurred between age and the ratio (r = 0.15, P = 0.43).
Conclusion:
Using NaClO as a simple and rapid digestion method for diatom testing of water samples would be an excellent alternative to conventional methods. Although the method's diatom detection rate for the lung samples was not optimal, it was still shown to be a feasible method.
More Related Videos
Related Concept Videos
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Mixtures of Acids
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
Qualitative Analysis
For instance, group IV...
Titration of Polyprotic Base with a Strong Acid