Related Experiment Video
Updated: Oct 14, 2025

Murine Fetal Echocardiography
Published on: February 15, 2013
What Are the Double Lines of the Fetal Cavum Septi Pellucidi on Ultrasound?
Shannon Green1, Dolores H Pretorius1,2, Amanda Crouch2,3
1Department of Radiology, University of California, San Diego, San Diego, California, USA.
Objective:
To demonstrate the significance of the double line appearance of the septi pellucidi laminae (SPL) on fetal ultrasound.
Method:
A total of 522 uncomplicated singleton pregnancies (15 to 39 weeks' gestational age) with fetal ultrasounds were enrolled. The presence of a single versus double line SP as well as measurement of the cavum septi pellucidi (CSP) was determined retrospectively. Ultrasound settings from the CSP images were recorded. Thickness of the SPL was measured in 20 ultrasound and 14 MRI cases; histology was reviewed from one neonate. Maternal BMI and gestational age were also recorded.
Results:
The presence of double line SPL is a normal sonographic finding, seen in 47% (188/403) of normal fetuses. Thickness of the SPL in 10 cases with double line averaged 1.4 mm and in 10 cases with single line averaged 0.8 mm; MRI measurements were within 0.1 mm of the corresponding ultrasound measurements. Double line cavum was more often seen with mid-dynamic contrast range settings (5, 6) rather than high range settings (7-10) (P value <.05). The double line was only visualized on ultrasound when the angle of insonation was at or near perpendicular to the laminae; it was never visualized on coronal ultrasound imaging or MRI imaging.
Conclusion:
A double line septum pellucidum lamina is a normal finding seen in almost 50% of uncomplicated singleton pregnancies. It may be attributed to borders of cell layers within each lamina that form separate specular reflections on both sides; this can be accentuated by ultrasound settings and beam angulation.
Related Concept Videos
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Uterus and Cervix
The uterus is securely anchored within the pelvic cavity by paired broad ligaments on either side. It is further stabilized by three pairs...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):