Related Experiment Video
Updated: Oct 14, 2025

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Evaluation of the ocular safety associated with the exhalation delivery system with fluticasone
David P Skoner1, Eli O Meltzer2, Jonathan Skoner3
1From the Director, Section of Allergy and Immunology, West Virginia University Children's Hospital, Morgantown, West Virginia.
Abstract:
Background: Intranasal corticosteroids (INCS) are the cornerstone of treatment for chronic rhinosinusitis. Although INCS are generally considered safe and effective, there is a concern that chronic use may lead to ocular adverse effects. Objective: To assess ocular safety of the exhalation delivery system with fluticasone propionate (EDS-FLU) in patients with chronic rhinosinusitis with nasal polyps. Methods: Ocular safety data were collected during two randomized, double-blind, placebo controlled studies with open-label extensions. Ophthalmologists performed tonometry, slit-lamp, and visual acuity examinations to assess intraocular pressure (IOP) and the presence of cataracts. Ocular examinations were conducted before double-blind treatment, at the end of the 16-week double-blind phase, and at the end of the 8-week open-label phase. The results of pooled data from patients who received EDS-FLU 186 µg (n = 160), EDS-FLU 372 µg (n = 161), and EDS-placebo (n = 161) twice daily are reported here. Results: At the end of the double-blind phase, six patients developed elevated average IOP > 21 mm Hg: two patients (1.2%) in the EDS-placebo group, three patients (1.9%) in the EDS-FLU 186 µg group, and one patient (0.6%) in the EDS-FLU 372 µg group. In addition, 6 of 482 patients developed cataracts: 3 patients in the EDS-placebo group, 2 patients in the EDS-FLU 186 µg group, and 1 patient in the EDS-FLU 372 µg group. At the end of the open-label phase, two additional patients showed IOP > 21 mm Hg and two additional patients developed cataracts. Conclusion: No increased risk of elevated IOP was detected with EDS-FLU; the rate of cataract development was similar to EDS-placebo and to that reported with other INCS.Clinical trials NCT01622569 and NCT01624662,
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Related Concept Videos
Drug Delivery: Miscellaneous Routes
Oral inhalation and nasal sprays swiftly transfer drugs across the respiratory epithelium's mucosal layer. Inhaled glucocorticoids and bronchodilators directly target lung conditions such as asthma, while fluticasone nasal spray mitigates allergic rhinitis.
Transdermal patches transport drugs...
Antiasthma Drugs: Inhaled Corticosteroids and Glucocorticoids
ICS work through a multifaceted mechanism of action. They suppress the inflammatory response caused by the proliferation of TH cells. They also reduce the transcription of the IL-2 gene, which is involved in the...
Inhaled Medications
Inhalational Anesthetics: Overview
Additional Routes of Drug Administration
Administering drugs via inhalation allows for the direct delivery of gaseous, volatile substances or droplets to different parts of the respiratory tract. One of the advantages of the inhalation route is the rapid absorption of drugs into the circulatory system, which is possible because of the large surface area of...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...