Related factors for preserving firefighter's pulmonary function
Seonggyu Kim1, Ye-Eun Jeon1, Hyeseung Ryu1
1Department of Occupational and Environment Medicine, Keimyung University Dongsan Medical Center, Daegu, Korea.
Background:
Firefighters are constantly exposed to harmful substances in the respiratory tract and require management measures. We comprehensively compared factors affecting the lung function of firefighters to identify management measures that can reduce the deterioration of lung function.
Methods:
A cross-sectional study was conducted in 1,108 male firefighters. Subjects were surveyed with self-written questionnaires that included a history of smoking, number of workouts per week, work department, and medical history, including diseases that could affect lung function. Body mass index was calculated using an automatic body measurement instrument and body fat, body fat percentage, muscle mass, and skeletal muscle mass were measured using Inbody 770. Based on the body weight obtained from body measurements, skeletal muscle mass height-adjusted skeletal muscle index (hSMI) compared to height was determined. For lung function, forced expiratory volume in one second (FEV1), forced vital capacity (FVC), FEV1/FVC, and peak expiratory flow (PEF) were measured using a spirometer HI-801. Analysis of variance and independent t-tests were performed for univariate analysis of factors that could affect lung function, and multiple regression analysis was performed for multivariate analysis.
Results:
When the factors relating lung function were analyzed using regression analysis, FEV1 was negatively correlated with age, body fat percentage, and duty year, positively with height and hSMI. FVC increased with height and hSMI, decreased with age, body fat percentage, and duty year. FEV1/FVC was related with age, height, body fat percentage and working history. Height and muscle mass were analyzed as related factors on PEF. When the analysis was conducted on firefighters who exercised more than 3 times a week, working history had lower relation with FEV1 and body fat percentage had no relation with FEV1/FVC.
Conclusion:
We suggest management measures to reduce body fat percentage and increase skeletal muscle mass to maintain lung function in firefighters.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Chronic Obstructive Pulmonary Disease-I: Introduction
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...