Determination of Halogens by Ion Chromatography in Edible Mushrooms after Microwave-Induced Combustion for Sample Preparation
Related Experiment Video
Updated: Oct 14, 2025

Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
Gilberto Silva Coelho Junior1, Filipe Soares Rondan1, Carla Andrade Hartwig1
1Centro de Ciências Químicas, Farmacêuticas e de Alimentos, Universidade Federal de Pelotas, Capão do Leão 96160-000, RS, Brazil.
Abstract:
In this study, the microwave-induced combustion (MIC) method was evaluated for the sample preparation of the most consumed mushroom species in Brazil (Champignon, Shiitake, and Shimeji) and further halogen determination by ion chromatography (IC). For this, sample mass, combustion aid mass, and absorbing solution (H2O and 50 mmol·L-1, 100 mmol·L-1, or 150 mmol·L-1 NH4OH) were evaluated. Bromine and iodine concentrations, determined by IC, were lower than the limits of detection (LODs, Br: 6 mg·kg-1 and I: 24 mg·kg-1). Inductively coupled plasma mass spectrometry (ICP-MS) was also used for Br and I determination, and the LODs were lower (Br: 0.066 mg·kg-1 and I: 0.014 mg·kg-1) than those obtained by IC. Concentrations of Cl, obtained by IC, ranged from 523 mg·kg-1 to 13053 mg·kg-1 with LOD of 40 mg·kg-1. In turn, Br and I concentrations, obtained by ICP-MS, ranged from 2.49 mg·kg-1 to 5.50 mg·kg-1 and from <0.014 mg·kg-1 to 0.047 mg·kg-1, respectively. Fluorine concentrations, determined by IC, were always lower than LOD (23 mg·kg-1). The trueness of the proposed methods was evaluated by recovery tests using standard solutions and a reference material (RM NIST 8435). When using the standard solution, recoveries ranged from 95% to 103% for halogen determination by IC and from 105% to 109% for Br and I determination by ICP-MS. When using the RM, recoveries of 102% for Cl by IC and of 87% and 86% for Br and I by ICP-MS, respectively, were obtained.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Flame Photometry: Lab
Mass Spectrometry: Alkyl Halide Fragmentation