Soft contact lens-induced corneal deformation in the posterior corneal surface
Motohiro Itoi1, Motozumi Itoi2
1Department of Ophthalmology, Kyoto Prefectural University of Medicine, 465 Kawaramachi Hirokoji Kamigyo-ku, Kyoto, Japan; Dougenzaka Itoi Eye Clinic, Itoi Building 1-10-19 Dougenzaka Shibuya-ku, Tokyo, Japan.
Objective:
This case report aims to highlight the corneal deformation induced by soft contact lens (SCL) wear, which is accompanied by changes in not only the anterior but also the posterior surface of cornea.
Case Report:
Cases are presented of two patients who wore non- planned replacement SCL for more than 15 years fabricated from materials with low oxygen permeability, sought a consultation with complaints of visual acuity loss in the both eyes. Anterior segment optical coherence tomography imaging demonstrated corneal deformation in the posterior as well as the anterior surface in both eyes of two patients, resulting in the diagnosis of corneal deformation induced by SCL wear. After the cessation of lens wear, there were improvements in visual acuity, anterior and posterior corneal higher-order aberrations, and changes in the anterior corneal shape, whereas the posterior corneal shape was improved in one case and remained mildly deformed in the other case.
Conclusion:
Wearing SCLs with low oxygen permeability for long time periods, could induce corneal deformation in patients, indicating the need for careful observation of changes in not only the anterior but also the posterior corneal surface.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
04:00Author Spotlight: Establishing a Practical and Cost-Effective Protocol for Corneal Sensitivity Testing in Clinical Settings
Published on: August 2, 2024
Related Concept Videos
Deformations in a Transverse Cross Section
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Plastic Deformations
Focusing of Light in the Eye
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Deformations in a Symmetric Member in Bending
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Temperature Dependent Deformation