Related Experiment Video
Updated: Oct 13, 2025

Simplified Whole Body Plethysmography to Characterize Lung Function During Respiratory Melioidosis
Published on: February 24, 2023
Respiratory morbidities and lung function abnormalities in survivors of Bhopal Gas Disaster: A cross-sectional study
Sajal De1, Nalok Banerjee1, Yogesh Sabde1
1National Institute for Research in Environmental Health, Kamla Nehru Hospital Building, Gandhi Medical College Campus, Bhopal, 462001, India.
Background:
Respiratory morbidities remained significant for the last four decades among the survivors of the Bhopal gas disaster. We hypothesized that lung function abnormalities, especially small airway dysfunctions, were responsible for the ongoing respiratory morbidities.
Methods:
We conducted a cross-sectional study between 2018 and 2020 in the severely exposed cohort of the Bhopal gas disaster. A standardized questionnaire was used to record their respiratory symptoms. The forced oscillometry (FOT) and spirometry were utilized for assessing lung functions. Univariate and multivariate logistic regression analyses were used to examine the association.
Results:
Of 916 enrolled individuals (men: 442, mean age: 55.2 ± 12.3 years), 558 participated in lung function assessments. Breathlessness was the most common complaint (71.7%), followed by cough (15.1%). The R5 > upper limit of normal (ULN), R5-19 > ULN, and X5 < lower limit of normal (LLN) were observed in 29.3%, 23.3%, and 21.2% participants, respectively. Normal, obstructive, and restrictive spirometry was observed in 46.2%, 26.1%, and 27.7%, participants, respectively. FOT parameters were abnormal in 25.3% individuals with normal spirometry. Individuals with obstructive spirometry had the highest risk of having abnormal FOT parameters (adjusted odds ratio [adj OR]:3.93, 95% confidence interval [CI]: 2.24-6.89). Breathlessness showed a significant association with abnormal R5 (adj OR: 1.81; 95% CI: 1.13-2.91) and obstructive spirometry (adj OR: 2.26; 95% CI: 1.29-3.95).
Conclusions:
Assessment of small airway functions along with spirometry are useful to identify complex lung function abnormalities in cases of toxic inhalation.
More Related Videos
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
14:48Visualizing Lung Cellular Adaptations during Combined Ozone and LPS Induced Murine Acute Lung Injury
Published on: March 21, 2021
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Other Pulmonary Disorders
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Acute Respiratory Failure-IV
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...