Jos M B M van der Vossen1, Margreet Heerikhuisen1, Roberto A A L Traversari2
1The Netherlands Organisation for Applied Scientific Research TNO, department of Microbiology and Systems Biology, Utrechtseweg 48, 3704 HE Zeist, the Netherlands.
Background:
Because of the enormous demand for personal protective equipment and especially respiratory protective devices (respirators) during the initial phase of the corona pandemic shortages arose. Sterilisation of used respirators can reduce these shortages. In our study, respirator testing was carried out after only one sterilisation cycle.
Aim:
To determine if steam sterilisation and reuse could be safely applied for used respirators.
Methods:
In a cabinet an aqueous solution of NaCl (0.02% w/v) was nebulized and passed through a sample of the material of a respirator. Passing particle concentrations were measured directly from the cabinet and via the filter material of the respirator for particles ≥ 0.3 μm, ≥ 0.5 μm and ≥ 1.0 μm.
Findings:
only three out of ten steam sterilised respirators met the requirements of 94% filtration efficiency.
Conclusion:
The results prove that heat sterilisation cannot be generically applied for reuse of respirators safely.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Filtration
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...