Related Experiment Video
Updated: Oct 13, 2025

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Implications of Diagnostic Drops on Scheimpflug Tomography: The Proper Order for Clinical Testing
Prema Padmanabhan1, Michael W Belin2, Rachapalle Reddi Sudhir1
1Department of Cornea & Refractive Surgery, Medical Research Foundation, Sankara Nethralaya, Chennai, Tamil Nadu, India.
Purpose:
The purpose of this article was to study the impact of instillation of 1% fluorescein and mydriatics on measurements made by Scheimpflug imaging.
Methods:
This was a cross-sectional study of patients who had measurements of corneal shape (maximum keratometry and best fit sphere of anterior and posterior corneal surfaces), pachymetry (at the pupil center, corneal apex, and thinnest location), and anterior chamber parameters (depth, volume, and angle of anterior chamber and corneal volume) using the Pentacam HR before and after the instillation of fluorescein and mydriatics. Group A had baseline measurements that were repeated 1.5 hours after the instillation of 1% fluorescein and 0.8% tropicamide+ 5% phenylephrine eye drops. Group B had baseline measurements that were repeated 10 minutes after the instillation of 1% fluorescein, and group C had baseline measurements that were repeated 1.5 hours after the instillation of mydriatics.
Results:
Overall, 131 eyes of 131 patients were studied: 87 in group A, 28 in group B, and 16 in group C. Significant differences and wide variations were noted in corneal pachymetry and anterior chamber parameters in all 3 groups. The highest magnitude and range of difference was observed in pachymetry at the pupil center (17 ± 53.5 μm) and in anterior chamber volume (26.7 ± 69.8 mm 3 ). Corneal shape measurements of anterior and posterior corneal surfaces were not significantly affected by either fluorescein or mydriatics. Pupillary dilation also affected the ability of the Pentacam to accurately trace the pupil margin in 19.5% of cases.
Conclusions:
For consistent and accurate measurements, it is important that Scheimpflug imaging be performed before other tests which may need the instillation of fluorescein or mydriatics.
Related Concept Videos
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies III: Computed Tomography
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

