Related Experiment Video
Updated: Oct 13, 2025

An Application for Pairing with Wearable Devices to Monitor Personal Health Status
Published on: February 3, 2022
A randomized cross-over trial investigating differences in 24-h personal air and skin temperatures using wearable
Andria Constantinou1, Stavros Oikonomou1, Corina Konstantinou1
1Cyprus International Institute for Environmental and Public Health, Cyprus University of Technology, Limassol, Cyprus.
Abstract:
The influence of elevated air temperatures recorded in various urban microenvironments in adversely impacting biologically relevant disease end points has not yet been extensively tackled. This study is a post hoc analysis of the TEMP pilot trial, a randomized 2 × 2 cross-over trial that examined changes in metabolic and stress hormonal profiles of healthy adults in two settings (urban vs. rural) with distinctly different climatological characteristics during the Mediterranean summer. This analysis aimed to study the association between the 24-h personal air or skin temperature sensor measurements and the diary-based location type (indoors vs. outdoors) in urban (seaside) vs. rural (higher in altitude) microenvironments. Out of 41 eligible participants, a total of 37 participants were included in this post-hoc TEMP trial analysis. Wearable sensors recorded personal air temperature, skin temperature, and activity (as a surrogate marker of physical activity) in each setting, while a time-stamped personal diary recorded the types of indoor or outdoor activities. Temperature peaks during the 24-h sampling period were detected using a peak finding algorithm. Mixed effect logistic regression models were fitted for the odds of participant location (being indoors vs. outdoors) as a function of setting (urban vs. rural) and sensor-based personal temperature data (either raw temperature values or number of temperature peaks). During the study period (July-end of September), median [interquartile range, IQR] personal air temperature in the rural (higher altitude) settings was 1.5 °C lower than that in the urban settings (27.1 °C [25.4, 29.2] vs. 28.6 °C [27.1, 30.5], p < 0.001), being consistent with the Mediterranean climate. Median [IQR] personal air temperature in indoor (micro)environments was lower than those in outdoors (28.0 °C [26.4, 30.3] vs 28.5 °C [26.8, 30.7], p < 0.001). However, median [IQR] skin temperature was higher in indoor (micro)environments vs. outdoors (34.8 °C [34.0, 35.6] and 33.9 °C [32.9, 34.8], p < 0.001) and the number of both personal air and skin temperature peaks was higher indoors compared to outdoors (median [IQR] 3.0 [2.0,4.0] vs 1.0 [1.0,1.3], p < 0.007, for the skin sensors). A significant association between the number of temperature peaks and indoor location types was observed with either the personal air sensor (OR 3.1; 95% CI 1.2-8.2; p = 0.02) or the skin sensor (OR 3.7; 95% CI 1.4-9.9; p = 0.01), suggesting higher number of indoor air temperature fluctuations. Amidst the global climate crisis, more population health studies or personalized medicine approaches that utilize continuous tracking of individual-level air/skin temperatures in both indoor/outdoor locations would be warranted, if we were to better characterize the disease phenotype in response to climate change manifestations.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.

