Related Experiment Video
Updated: Oct 13, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
In training emergency physicians the carotid artery Doppler with passive leg raise, does previous sonographic
Robert Osgood1,2, Sangeeth Mohan1,3, Lisa John1,4
1Emergency Department Metro South Health Logan Hospital Meadowbrook Queensland Australia.
Background:
Determination of fluid responsiveness (FR) associated with intravascular fluid resuscitation in hypotensive patients poses a challenge, with current best evidence methods fraught with poor retest reliability and difficulty in image acquisition (Osman, Crit Care Med 2007; 35: 64; Marik, Crit Care Med 2009; 37: 2642). Doppler carotid blood flow with passive leg raise (PLR) is a recent modality for determining FR (Marik, Chest 2013; 143: 364).
Purpose:
This study aimed to determine whether emergency physicians with limited ultrasound experience can reliably acquire this skill.
Method:
This prospective study recruited 60 emergency physicians with varying experience, who underwent a 3-step learning programme. Participants performed carotid velocity time integral (VTi) Doppler on healthy subjects, followed by repeat measurements in the PLR position. A 16-point checklist and time recorded were assessed for each sonographer, with each participant completing a post-study questionnaire to evaluate perceived competence and ease of skill acquisition.
Results:
Of the 60 emergency physicians recruited, 37 (61.6%) were inexperienced and 23 (38.4%) were experienced. Against the 16-point assessment, 61% completed assessment without any errors. Fifty-six out of 60 (94.3%) completed the assessment to acceptable standard with errors recognised and corrected, and four participants (6.7%) made critical errors without correction (Figure 1). Average (±SEM) total scan time was 4:52 ± 0:19, with no significant difference found between inexperienced and experienced groups.
Conclusions:
This study demonstrated feasibility to train emergency physicians, demonstrating that average FR assessment was obtained within 5 min, with no difference between prior experience in scan quality/time taken. 94% completed the scan to acceptable standards, demonstrating ease of carotid Doppler flow with PLR to provide critical information in management of the hypotensive patient.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pre-Procedural Guidelines for Assessing Blood Pressure