Related Experiment Video
Updated: Oct 13, 2025

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
Value of D-Dimer as a Diagnostic Marker of Infection Associated with Orthopedic Implants
Adel Ebrahimpour1, Mohammad Ali Okhovatpour1, Ali Tabrizi2
1Department of Orthopedic Surgery, Shohadaye Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Background:
Recently, the D-dimer biomarker has gained the researchers' attention for predicting infections. We aimed to determine the relationship between this marker and other inflammatory markers involved in orthopedic implant-associated infections.
Materials And Methods:
In this study, all patients diagnosed with an orthopedic implant-associated infection were investigated in 3 years. The serum level of D-dimer, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) was measured. Infection was diagnosed based on the clinical and culture results of biopsy samples.
Results:
The cultured microorganisms, detected in 26 patients with infections, included Staphylococcus aureus (n = 13, 50%), Staphylococcus epidermidis (n = 2, 7.7%), Klebsiella aerogenes (n = 8, 30.8%), and Pseudomonas aeruginosa (n = 3, 11. 5%). Based on laboratory findings, there was a significant difference in the CRP level and ESR (P = 0.001). Although the level of D-dimer was higher in infected patients, compared to the controls (992.6 ± 667.2 vs. 690.1 ± 250.2 ng/mL), the difference was not statistically significant. There was no significant correlation between the elevated D-dimer level and CRP level, whereas ESR had a positive correlation with the elevated D-dimer level (r = 0.6, P = 0.03). The sensitivity, specificity, and positive predictive value (PPV) of D-dimer in the prediction of infection were 65%, 57%, and 45%, respectively. Furthermore, the sensitivity, specificity, and PPV of CRP were 100%, 92.3%, and 95%, respectively, whereas the corresponding values for ESR were 85%, 69.2%, and 62%, respectively.
Conclusion:
Measurement of the serum D-dimer level is not efficient for the diagnosis of orthopedic implant-associated infections due to its low predictive value. Furthermore, there was no significant correlation between the serum D-dimer level and CRP.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Bacterial Signaling

