Evaluation of Apparent Noise on CT Images Using Moving Average Filters
Keisuke Fujii1,2, Keiichi Nomura3, Kuniharu Imai4
1Nagoya University Graduate School of Medicine, 1-1-20 Daiko-Minami, Higashi-ku, Nagoya, Aichi, 461-8673, Japan. fujii@met.nagoya-u.ac.jp.
Abstract:
This study aims to devise a simple method for evaluating the magnitude of texture noise (apparent noise) observed on computed tomography (CT) images scanned at a low radiation dose and reconstructed using iterative reconstruction (IR) and deep learning reconstruction (DLR) algorithms, and to evaluate the apparent noise in CT images reconstructed using the filtered back projection (FBP), IR, and two types of DLR (AiCE Body and AiCE Body Sharp) algorithms. We set a square region of interest (ROI) on CT images of standard- and obese-sized low-contrast phantoms, slid different-sized moving average filters in the ROI vertically and horizontally in steps of 1 pixel, and calculated the standard deviation (SD) of the mean CT values for each filter size. The SD of the mean CT values was fitted with a curve inversely proportional to the filter size, and an apparent noise index was determined from the curve-fitting formula. The apparent noise index of AiCE Body Sharp images for a given mAs value was approximately 58, 23, and 18% lower than that of the FBP, AIDR 3D, and AiCE Body images, respectively. The apparent noise index was considered to reflect noise power spectrum values at lower spatial frequency. Moreover, the apparent noise index was inversely proportional to the square roots of the mAs values. Thus, the apparent noise index could be a useful indicator to quantify and compare texture noise on CT images obtained with different scan parameters and reconstruction algorithms.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT