Acoustic radiation force impulse elastography and liver fibrosis risk scores in severe obesity
Roberto Gomes da Silva1, Maria Luiza Queiroz de Miranda2, Paulo Eugênio de Araújo Caldeira Brant2
1Departamento de Medicina, Unidade de Gastroenterologia, Faculdade de Ciências Médicas da Santa Casa de São Paulo, São Paulo, SP, Brasil, contato@drrobertogomes.com.br.
Objective:
Identifying significant fibrosis is crucial to evaluate the prognosis and therapeutic interventions in patients with nonalcoholic fatty liver disease (NAFLD). We assessed the performance of acoustic radiation force impulse (ARFI) elastography, APRI, FIB-4, Forns, NFS and BARD scores in determining liver fibrosis in severe obesity.
Methods:
A prospective study included 108 patients undergoing bariatric surgery. Liver biopsy specimens were obtained intraoperatively and classified according to the NAFLD Activity Score. Patients were assessed with serological markers and shear wave velocity of the liver was measured with the Siemens S2000 ultrasound system preoperatively. Optimal cut-off values were determined using the area under the receiver operating characteristic curves (AUROC).
Results:
In the entire cohort prevalence of NAFLD was 80.6%, steatohepatitis 25.9% and significant fibrosis 19.4%. The best tests for predicting significant fibrosis were FIB-4 and Forns scores (both AUROC 0.78), followed by APRI (AUROC 0.74), NFS (AUROC 0.68), BARD (AUROC 0.64) and ARFI (AUROC 0.62). ARFI elastography was successful in 73% of the patients. Higher body mass index (BMI) correlated with invalid ARFI measurements. In patients with BMI < 42 kg/m2, ARFI showed 92.3% sensitivity and 82,6% specificity for the presence of significant fibrosis, with AUROC 0.86 and cut-off 1.32 m/s.
Conclusion:
FIB-4 and Forns scores were the most accurate for the prediction of significant fibrosis in bariatric patients. Applicability and accuracy of ARFI was limited in individuals with severe obesity. In patients with BMI < 42 kg/m2, ARFI elastography was capable for predicting significant fibrosis with relevant accuracy.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection....