Related Experiment Video
Updated: Oct 13, 2025

Digital Planimetry for Assessing Wound Closure Kinetics in a Mouse Model
Published on: January 10, 2025
The application value of computed tomography and magnetic resonance imaging sinography/fistulography in evaluating
Hanqi Wang1, Aobuliaximu Yakupu2, Xian Ma2
1Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Background:
Chronic wounds are a worldwide health problem, with traditional imaging techniques failing in their accurate evaluation. Therefore, an effective imaging evaluation method is needed for the diagnosis and treatment or chronic wounds. This study is to investigate the application value of computed tomography (CT) and magnetic resonance imaging (MRI) sinography/fistulography in assessing the morphology and deep features of chronic wounds.
Methods:
We prospectively enrolled 43 chronic wounds patients who received both CT and MRI sinography/fistulography. The morphology and deep features of chronic wound on CT and MRI images were independently evaluated by 2 experienced radiologists. Kappa value and intraclass correlation coefficient (ICC) were calculated to evaluate the interobserver agreement and the consistency between CT and MRI sinography/fistulography in assessing the shape, number of branches, and involvement of body cavity and bones of chronic wounds.
Results:
There were substantial to almost perfect interobserver agreements for both CT and MRI sinography/fistulography in evaluating the morphology and deep features of chronic wounds. The consistency between CT and MRI was almost perfect for the 2 readers in evaluating the shape (reader 1, kappa value =1.000; reader 2, kappa value =0.932) and the number of branches [reader 1, ICC =0.951 (95% confidence interval: 0.909-0.973, P<0.001); reader 2, ICC =0.874 (95% confidence interval: 0.768-0.932, P<0.001)], and substantial to almost perfect when evaluating the involvement of body cavity (reader 1, kappa value =0.728; reader 2, kappa value =0.775) and bones (reader 1, kappa value =0.659; reader 2, kappa value =0.860).
Conclusions:
There was good interobserver agreement and consistency between CT and MRI sinography/fistulography in evaluating the morphology and deep features of chronic wounds.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies