Predictors and Impact of Low Diastolic Blood Pressure and Widened Pulse Pressure Following Transcatheter Aortic Valve

Puja B Parikh1, Jamie L Romeiser2, Britney Dhautel2

  • 1Department of Medicine, Stony Brook Renaissance School of Medicine, Stony Brook, NY, United States of America.

Abstract

Related Concept Videos

Aortic Regurgitation II: Clinical Features and Diagnostic Tests01:22

Aortic Regurgitation II: Clinical Features and Diagnostic Tests

Aortic valve regurgitation (AR) occurs when the aortic valve fails to close properly, allowing blood to flow backward from the aorta into the left ventricle. This backflow can result in two distinct clinical presentations: acute and chronic AR, each characterized by its own set of symptoms and physical findings.Acute Aortic RegurgitationAcute AR presents with a sudden onset of severe symptoms. Patients typically experience profound dyspnea (shortness of breath), chest pain, and signs of left...
76
Blood Pressure01:24

Blood Pressure

The movement of blood in a human body, commonly referred to as blood flow, is determined by the volume of blood that traverses a certain section of the bodily system per unit time. It is the rhythmic contraction of the heart's ventricles that primarily instigates this movement. As the ventricles contract, blood is forced into the prominent arteries, which then flow from areas of greater pressure to lower pressure areas. This movement continues into smaller arteries and arterioles and...
6.4K
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.8K
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1000
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.8K
Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
1.3K