Influence of pH value and salts on the adsorption of lysozyme in mixed-mode chromatography
Jannette Kreusser1, Fabian Jirasek1, Hans Hasse1
1Laboratory of Engineering Thermodynamics (LTD) TU Kaiserslautern Kaiserslautern Germany.
Abstract:
Mixed-mode chromatography (MMC) is an interesting technique for challenging protein separation processes which typically combines adsorption mechanisms of ion exchange (IEC) and hydrophobic interaction chromatography (HIC). Adsorption equilibria in MMC depend on multiple parameters but systematic studies on their influence are scarce. In the present work, the influence of the pH value and ionic strengths up to 3000 mM of four technically relevant salts (sodium chloride, sodium sulfate, ammonium chloride, and ammonium sulfate) on the lysozyme adsorption on the mixed-mode resin Toyopearl MX-Trp-650M was studied systematically at 25℃. Equilibrium adsorption isotherms at pH 5.0 and 6.0 were measured and compared to experimental data at pH 7.0 from previous work. For all pH values, an exponential decay of the lysozyme loading with increasing ionic strength was observed. The influence of the pH value was found to depend significantly on the ionic strength with the strongest influence at low ionic strengths where increasing pH values lead to decreasing lysozyme loadings. Furthermore, a mathematical model that describes the influence of salts and the pH value on the adsorption of lysozyme in MMC is presented. The model enables predicting adsorption isotherms of lysozyme on Toyopearl MX-Trp-650M for a broad range of technically relevant conditions.
More Related Videos
07:22How to Stabilize Protein: Stability Screens for Thermal Shift Assays and Nano Differential Scanning Fluorimetry in the Virus-X Project
Published on: February 11, 2019
12:38Crystallization of Proteins on Chip by Microdialysis for In Situ X-ray Diffraction Studies
Published on: April 11, 2021
Related Concept Videos
Analyte Adsorption and Distribution
Extraction: Advanced Methods
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Affinity Chromatography