Related Experiment Video
Updated: Oct 13, 2025

Evaluating the Effect of Roadside Parking on a Dual-Direction Urban Street
Published on: January 20, 2023
Ventilation and Pollutant Concentration for the Pedestrian Zone, the Near-Wall Zone, and the Canopy Layer at Urban
Mingjie Zhang1, Zhi Gao2,1, Xin Guo1
1School of Architecture and Urban Planning, Nanjing University, 22 Hankou Road, Nanjing 210093, China.
Abstract:
To gain further insight into the ventilation at urban street intersections, this study conducted 3D simulations of the ventilation at right- and oblique-angled intersections under eight wind directions by using the Reynolds-averaged Navier-Stokes (RANS) κ-ε turbulence model. The divergent responses of ventilation and pollution concentration for the pedestrian zone (ped), the near-wall zone (nwz), and the canopy layer to the change in intersection typology and wind direction were investigated. The flow characteristics of the intersections, taken as the air flow hub, were explored by employing indices such as the minimum flow ratio (β) between horizontal openings. The results show that oblique wind directions lead to a lower total volumetric flow rate (Qtotal) but a higher β value for right-angled intersections. For T-shaped intersections, a larger cross-sectional area for the outflow helps to increase Qtotal. Oblique-angled intersections, for example, the X-shaped intersection, experience a more significant difference in Qtotal but a steady value of β when the wind direction changes. The vertical air-exchange rate for the intersection was particularly significant when the wind directions were parallel to the street orientation or when there was no opening in the inflow direction. The spatially averaged normalized pollutant concentration and age of air (τ*¯) for the pedestrian zone and the canopy layer showed similar changing trends for most of the cases, while in some cases, only the τped*¯ or τnwz*¯ changed obviously. These findings reveal the impact mechanism of intersection configuration on urban local ventilation and pollutant diffusion.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical...

