Related Experiment Video
Updated: Oct 13, 2025

Author Spotlight: Advancing Prostate Cancer Research Through Improved Tissue Sampling and Biobanking
Published on: November 17, 2023
Significant Inter- and Intralaboratory Variation in Gleason Grading of Prostate Cancer: A Nationwide Study of 35,258
Rachel N Flach1, Peter-Paul M Willemse1, Britt B M Suelmann2
1Department of Oncological Urology, Cancer Center, University Medical Centre Utrecht, 3508 Utrecht, The Netherlands.
Purpose:
Our aim was to analyze grading variation between pathology laboratories and between pathologists within individual laboratories using nationwide real-life data.
Methods:
We retrieved synoptic (n = 13,397) and narrative (n = 29,377) needle biopsy reports from the Dutch Pathology Registry and prostate-specific antigen values from The Netherlands Cancer Registration for prostate cancer patients diagnosed between January 2017 and December 2019. We determined laboratory-specific proportions per histologic grade and unadjusted odds ratios (ORs) for International Society of Urological Pathologists Grades 1 vs. 2-5 for 40 laboratories due to treatment implications for higher grades. Pathologist-specific proportions were determined for 21 laboratories that consented to this part of analysis. The synoptic reports of 21 laboratories were used for analysis of case-mix correction for PSA, age, year of diagnosis, number of biopsies and positive cores.
Results:
A total of 38,321 reports of 35,258 patients were included. Grade 1 ranged between 19.7% and 44.3% per laboratory (national mean = 34.1%). Out of 40 laboratories, 22 (55%) reported a significantly deviant OR, ranging from 0.48 (95% confidence interval (CI) 0.39-0.59) to 1.54 (CI 1.22-1.93). Case-mix correction was performed for 10,294 reports, altering the status of 3/21 (14%) laboratories, but increasing the observed variation (20.8% vs. 17.7%). Within 15/21 (71%) of laboratories, significant inter-pathologist variation existed.
Conclusion:
Substantial variation in prostate cancer grading was observed between and within Dutch pathology laboratories. Case-mix correction did not explain the variation. Better standardization of prostate cancer grading is warranted to optimize and harmonize treatment.