Experimental Protocol to Investigate Particle Aerosolization of a Product Under Abrasion and Under Environmental Weathering
Published on: September 16, 2016
Understanding the Effect of Introducing Micro- and Nanoparticle Bismuth Oxide (Bi2O3) on the Gamma Ray Shielding
Mohamed A El-Nahal1, Mohamed Elsafi2, M I Sayyed3,4
1Department of Environmental Studies, Institute of Graduate Studies and Research, Alexandria University, Alexandria 21526, Egypt.
Abstract:
The aim of this study is to investigate the radiation shielding properties of novel concrete samples with bulk Bi2O3 and Bi2O3 nanoparticles (Bi2O3 NP) incorporated into its composition. The mass attenuation coefficient of the concrete samples without Bi2O3 and with 5 and 7 wt% bulk Bi2O3 were experimentally determined and were compared against values obtained using the XCOM and Geant4 simulations. Both methods greatly agree with the experimental values. The linear attenuation coefficients (LAC) of blank concrete (C-0), concrete with 5% bulk Bi2O3 (C-B5), and concrete with 5% nanoparticle Bi2O3 (C-N5) were determined and compared at a wide energy range. We found that the LAC follows the trend of C-0 < C-B5 < C-N5 at all the tested energies. Since both C-B5 and C-N5 have a greater LAC than C-0, these results indicate that the addition of Bi2O3 improves the shielding ability of the concretes. In addition, we investigated the influence of nanoparticle Bi2O3 on the LAC of the concretes. The half-value layer (HVL) for the concretes with bulk Bi2O3 and Bi2O3 nanoparticles is also investigated. At all energies, the C-0 has the greatest HVL, while C-N15 has the least. Thus, C-N15 concrete is the most space efficient, while C-0 is the least space efficient. The radiation protection efficiency (RPE) of the prepared concretes was found to decrease with increasing energy for all five samples. For C-0, the RPE decreased from 63.3% at 0.060 MeV to 13.48% at 1.408 MeV, while for C-N15, the RPE decreased from 87.9 to 15.09% for the same respective energies. Additionally, C-N5 had a greater RPE than C-B5, this result demonstrates that Bi2O3 NP are more efficient at shielding radiation than bulk Bi2O3.
More Related Videos
09:23Removal of Trace Elements by Cupric Oxide Nanoparticles from Uranium In Situ Recovery Bleed Water and Its Effect on Cell Viability
Published on: June 21, 2015
05:38Production and Analysis of Sporosarcina pasteurii Biocement Bricks Using Custom 3D-Printed Molds for Unconfined Compression Tests
Published on: March 7, 2025
Related Concept Videos
Waterproofing and Anti-Bacterial Admixtures in Concrete
Waterproofing admixtures render concrete hydrophobic,...
Permeability of Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Microcracking in Concrete
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...