Related Experiment Video
Updated: Oct 13, 2025

Real-Time Monitoring of Neurocritical Patients with Diffuse Optical Spectroscopies
Published on: November 19, 2020
Sleep-disordered breathing and ventilatory chemosensitivity in first ischaemic stroke patients: a prospective cohort
Sébastien Baillieul1, Sébastien Bailly2, Olivier Detante3,4
1Univ. Grenoble Alpes, Inserm, U1300, CHU Grenoble Alpes, Service Universitaire de Pneumologie Physiologie, 38000 Grenoble, France sbaillieul@chu-grenoble.fr.
Rationale:
Sleep-disordered breathing (SDB) is highly prevalent after stroke. The clinical and ventilatory chemosensitivity characteristics of SDB, namely obstructive, central and coexisting obstructive and central sleep apnoea (coexisting sleep apnoea) following stroke are poorly described.
Objective:
To determine the respective clinical and ventilatory chemosensitivity characteristics of SDB at least 3 months after a first ischaemic stroke.
Methods:
Cross-sectional analysis of a prospective, monocentric cohort conducted in a university hospital. 380 consecutive stroke or transient ischaemic attack patients were screened between December 2016 and December 2019.
Measurements And Main Results:
Full-night polysomnography, and hypercapnic ventilatory response were performed at a median (Q1; Q3) time from stroke onset of 134.5 (97.0; 227.3) days. 185 first-time stroke patients were included in the analysis. 94 (50.8%) patients presented no or mild SDB (Apnoea-Hypopnoea Index <15 events/hour of sleep) and 91 (49.2%) moderate to severe SDB, of which 52 (57.1%) presented obstructive sleep apnoea and 39 (42.9%) coexisting or central sleep apnoea. Obstructive sleep apnoea patients significantly differed regarding their clinical presentation from patients with no or mild SDB, whereas there was no difference with coexisting and central sleep apnoea patients. The latter presented a higher frequency of cerebellar lesions along with a heightened hypercapnic ventilatory response compared with no or mild SDB patients.
Conclusion:
SDB in first-time stroke patients differ in their presentation by their respective clinical traits and ventilatory chemosensitivity characteristics. The heightened hypercapnic ventilatory response in coexisting and central sleep apnoea stroke patients may orientate them to specific ventilatory support.
Related Concept Videos
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Acute Respiratory Failure-IV
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History

