Related Experiment Video
Updated: Oct 13, 2025

Direct-Coupled Electroretinogram DC-ERG for Recording the Light-Evoked Electrical Responses of the Mouse Retinal Pigment Epithelium
Published on: July 14, 2020
Replication of Reduced Pattern Electroretinogram Amplitudes in Depression With Improved Recording Parameters
Evelyn B N Friedel1,2,3, Ludger Tebartz van Elst1, Céline Schmelz4
1Department of Psychiatry and Psychotherapy, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Pattern electroretinogram (PERG) shows reduced retinal function in depression. A novel ratio method using specific stimulus sizes may offer an objective biomarker for major depressive disorder (MDD).
Area of Science:
- Neuroscience
- Ophthalmology
- Psychiatry
Background:
- The retina is increasingly studied in non-ophthalmological research.
- Pattern electroretinogram (PERG) assesses retinal ganglion cell function and has shown reduced contrast gain in depression.
- PERG responses vary with stimulus contrast, check size, and frequency, necessitating optimized recording procedures for psychiatric diagnostics.
Purpose of the Study:
- To evaluate optimized pattern electroretinogram (PERG) recording procedures for major depressive disorder (MDD) diagnostics.
- To investigate the impact of different stimulation frequencies and checkerboard sizes on PERG amplitudes in MDD patients.
- To explore the potential of PERG ratios as an objective biomarker for depression.
Main Methods:
- A pilot study involving 12 patients with major depressive disorder (MDD) and 12 healthy controls.
- PERG amplitudes were recorded using two steady-state pattern reversal frequencies (12.5/18.75 rps) and four checkerboard sizes (0.8°, 1.6°, 3.2°, 16°).
- PERG ratios (0.8°/16°) were calculated, adapting a protocol used for early glaucoma detection.
Main Results:
- MDD patients exhibited smaller PERG amplitudes across all tested parameters, with stimulus-specific reductions.
- The most significant PERG amplitude decline in MDD was observed at higher frequencies and finer patterns.
- Significantly reduced PERG ratios (0.8°/16°) were found in MDD patients at the higher stimulation frequency (18.75 rps).
Conclusions:
- PERG response normalization using ratios shows promise as an objective biomarker for depression.
- This ratio-based approach may facilitate inter-individual assessments of PERG recordings in psychiatric disorders.
- Optimized PERG protocols, including specific check size ratios, could aid in the objective diagnosis of depressive states.