Related Experiment Video
Updated: Oct 13, 2025

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
Ultrasound Sample Entropy Imaging: A New Approach for Evaluating Hepatic Steatosis and Fibrosis
Hsien-Jung Chan1, Zhuhuang Zhou2, Jui Fang3
1Department of Medical Imaging and Radiological SciencesCollege of Medicine, Chang Gung University Taoyuan 333323 Taiwan.
Abstract:
Objective: Hepatic steatosis causes nonalcoholic fatty liver disease and may progress to fibrosis. Ultrasound is the first-line approach to examining hepatic steatosis. Fatty droplets in the liver parenchyma alter ultrasound radiofrequency (RF) signal statistical properties. This study proposes using sample entropy, a measure of irregularity in time-series data determined by the dimension [Formula: see text] and tolerance [Formula: see text], for ultrasound parametric imaging of hepatic steatosis and fibrosis. Methods: Liver donors and patients were enrolled, and their hepatic fat fraction (HFF) ([Formula: see text]), steatosis grade ([Formula: see text]), and fibrosis score ([Formula: see text]) were measured to verify the results of sample entropy imaging using sliding-window processing of ultrasound RF data. Results: The sample entropy calculated using [Formula: see text] 4 and [Formula: see text] was highly correlated with the HFF when a small window with a side length of one pulse was used. The areas under the receiver operating characteristic curve for detecting hepatic steatosis that was [Formula: see text]mild, [Formula: see text]moderate, and [Formula: see text]severe were 0.86, 0.90, and 0.88, respectively, and the area was 0.87 for detecting liver fibrosis in individuals with significant steatosis. Discussion/Conclusions: Ultrasound sample entropy imaging enables the identification of time-series patterns in RF signals received from the liver. The algorithmic scheme proposed in this study is compatible with general ultrasound pulse-echo systems, allowing clinical fibrosis risk evaluations of individuals with developing hepatic steatosis.
More Related Videos
06:09Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
Published on: July 21, 2023
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography