Related Experiment Video
Updated: Oct 13, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Marginal gaps and internal voids after root-end filling using three calcium silicate-based materials: A Micro-CT
Alexander Pompermayer Jardine1, Ketsia Fernanda Váz Rosa2, Felipe Barros Matoso1
1Graduate Program of School of Dentistry/Endodontics, Federal University of Rio Grande do Sul(UFRGS), Porto Alegre, RS, Brazil.
This study compared three calcium silicate-based materials for root-end filling. Micro-CT scans revealed no significant differences in marginal gaps or internal voids among MTA Angelus, Biodentine, and Neo MTA Plus.
Area of Science:
- Endodontics
- Dental Materials Science
- 3D Imaging in Dentistry
Background:
- Root-end filling is crucial for the success of apical surgery.
- Calcium silicate-based materials are commonly used for their sealing properties.
- Assessing the 3D quality of these fillings is essential for clinical predictability.
Purpose of the Study:
- To evaluate and compare the 3D quality of root-end fillings using three calcium silicate-based materials.
- To quantify marginal gaps and internal voids in retrofilled cavities.
- To determine if there are significant differences in defect formation between MTA Angelus, Biodentine, and Neo MTA Plus.
Main Methods:
- Thirty human single-rooted teeth underwent root canal treatment and retro-filling with MTA Angelus, Biodentine, or Neo MTA Plus.
- Micro-computed tomography (micro-CT) scans were performed before and after filling.
- Marginal gap volume/percentage and internal void volume/percentage were quantified and statistically analyzed.
Main Results:
- No statistically significant differences were found between the three materials regarding marginal gaps, internal voids, or overall defects.
- Median overall defect volume was 0.004mm³ (1.749%) for MTA Angelus, 0.018mm³ (6.660%) for Biodentine, and 0.012mm³ (4.079%) for Neo MTA Plus.
- All tested materials exhibited some degree of gaps and/or voids.
Conclusions:
- MTA Angelus, Biodentine, and Neo MTA Plus demonstrated comparable 3D quality in terms of marginal gap and internal void formation.
- Further research may explore long-term sealing ability and biocompatibility.
- Clinical selection may depend on factors beyond immediate volumetric defect assessment.
Related Concept Videos
Porosity in Cement Paste
The balance of water to cement in the mix is...
Total Voids in Concrete
Microcracking in Concrete
Soundness of Cement
Hydration of Cement
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...

