Mitigating Fugitive Aerosols During Aerosol Delivery via High-Flow Nasal Cannula Devices
Jie Li1, Amnah A Alolaiwat2, Lauren J Harnois2
1Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, Chicago, Illinois. Jie_Li@rush.edu.
Background:
Aerosol delivery via high-flow nasal cannula (HFNC) has attracted clinical interest in recent years. However, both HFNC and nebulization are categorized as aerosol-generating procedures (AGPs). In vitro studies raised concerns that AGPs had high transmission risk. Very few in vivo studies examined fugitive aerosols with nebulization via HFNC, and effective methods to mitigate aerosol dispersion are unknown.
Methods:
Two HFNC devices (Airvo 2 and Vapotherm) with or without a vibrating mesh nebulizer were compared; HFNC alone, surgical mask over HFNC interface, and HFNC with face tent scavenger were used in a random order for 9 healthy volunteers. Fugitive aerosol concentrations at sizes of 0.3-10.0 μm were continuously measured by particle sizers placed at 1 and 3 ft from participants. On a different day, 6 of the 9 participants received 6 additional nebulizer treatments via vibrating mesh nebulizer or small-volume nebulizer (SVN) with a face mask or a mouthpiece with/without an expiratory filter. In vitro simulation was employed to quantify inhaled dose of albuterol with vibrating mesh nebulizer via Airvo 2 and Vapotherm.
Results:
Compared to baseline, neither HFNC device generated higher aerosol concentrations. Compared to HFNC alone, vibrating mesh nebulizer via Airvo 2 generated higher 0.3-1.0 μm particles (all P < .05), but vibrating mesh nebulizer via Vapotherm did not. Concentrations of 1.0-3.0 μm particles with vibrating mesh nebulizer via Airvo 2 were similar with vibrating mesh nebulizer and a mouthpiece/face mask but less than SVN with a mouthpiece/face mask (all P < .05). Placing a surgical mask over HFNC during nebulization reduced 0.5-1.0 μm particles (all P < .05) to levels similar to the use of a nebulizer with mouthpiece and expiratory filter. In vitro the inhaled dose of albuterol with vibrating mesh nebulizer via Airvo 2 was ≥ 6 times higher than vibrating mesh nebulizer via Vapotherm.
Conclusions:
During aerosol delivery via HFNC, Airvo 2 generated higher inhaled dose and consequently higher fugitive aerosols than Vapotherm. Simple measures, such as placing a surgical mask over nasal cannula during nebulization via HFNC, could effectively reduce fugitive aerosol concentrations.
More Related Videos
07:28Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Inhaled Medications
Cardiopulmonary Resuscitation II: ACLS Airway Management