Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Steady, Laminar Flow Between Parallel Plates01:17

Steady, Laminar Flow Between Parallel Plates

452
Understanding steady, laminar flow between parallel plates is essential for analyzing and designing flow in narrow rectangular channels, commonly found in various water conveyance and drainage systems. The Navier-Stokes equations govern fluid motion and are generally challenging to solve due to their nonlinearity. However, simplifications are possible in certain cases, like the steady laminar flow between parallel plates. For this scenario, we assume steady, incompressible, laminar flow.
452

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Are Expectations in Breast Reconstruction Manageable? A Mixed-Methods GoBreast II Study on Women's Goals of Breast Reconstruction After Mastectomy.

Clinical breast cancer·2026
Same author

Gothenburg Breast reconstruction (GoBreast) II protocol: a Swedish partially randomised patient preference, superiority trial comparing autologous and implant-based breast reconstruction.

BMJ open·2024
Same author

A systematic review of randomised controlled trials in breast reconstruction.

Journal of plastic surgery and hand surgery·2024
Same author

Use of smart patches by athletes: A concise SWOT analysis.

Frontiers in physiology·2023
Same author

A Comparison of a Novel Stretchable Smart Patch for Measuring Runner's Step Rates with Existing Measuring Technologies.

Sensors (Basel, Switzerland)·2022
Same author

Docking and Activity of DNA Polymerase on Solid-State Nanopores.

ACS sensors·2022
Same journal

Application of ephrin-B2 loaded glycol chitosan-silk fibroin hydrogel in the treatment of diabetic refractory wounds.

Scientific reports·2026
Same journal

International expert Delphi consensus on thromboprophylaxis in metabolic and bariatric surgery.

Scientific reports·2026
Same journal

Assessing the cross-region knowledge transfer capability of selected deep learning building vectorization methods in the context of available training datasets.

Scientific reports·2026
Same journal

Feasibility and preliminary effects of outdoor versus indoor cognitive-motor therapy in women with Alzheimer's disease: A randomized single-blind pilot study.

Scientific reports·2026
Same journal

Hallmarks of social action in the vocal turn-taking of wild common marmosets (Callithrix jacchus).

Scientific reports·2026
Same journal

Role and mechanism of AOPPs-induced NOX4-mediated ferroptosis in intervertebral disc degeneration.

Scientific reports·2026
See all related articles

Related Experiment Video

Updated: Oct 12, 2025

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

21.3K

Microfluidic active pressure and flow stabiliser.

Simon Södergren1, Karolina Svensson2, Klas Hjort3

  • 1Microsystems Technology Division, Centre of Natural Hazard and Disaster Science (CNDS), Uppsala University, Box 35, 751 03, Uppsala, Sweden. simon.sodergren@angstrom.uu.se.

Scientific Reports
|November 19, 2021
PubMed
Summary
This summary is machine-generated.

This study introduces a novel high-pressure microfluidic stabilizer using flow capacitance and thermal viscosity control. It significantly improves pump stability and precision for reproducible microfluidic experiments.

More Related Videos

A Microfluidic-based Hydrodynamic Trap for Single Particles
10:13

A Microfluidic-based Hydrodynamic Trap for Single Particles

Published on: January 21, 2011

16.9K
Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology
07:03

Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology

Published on: December 1, 2023

1.1K

Related Experiment Videos

Last Updated: Oct 12, 2025

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

21.3K
A Microfluidic-based Hydrodynamic Trap for Single Particles
10:13

A Microfluidic-based Hydrodynamic Trap for Single Particles

Published on: January 21, 2011

16.9K
Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology
07:03

Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology

Published on: December 1, 2023

1.1K

Area of Science:

  • Microfluidics
  • Fluid Dynamics
  • Control Systems Engineering

Background:

  • Reproducibility in microfluidics is often limited by unstable pressures and flow rates.
  • Existing stabilizers are inadequate for high-pressure microfluidic applications and long-term fluctuations.
  • There is a need for advanced stabilization methods in microfluidic systems.

Purpose of the Study:

  • To present a novel stabilization method for high-pressure microfluidic systems.
  • To demonstrate improved stability and precision in microfluidic flow rates.
  • To enable integration into lab-on-a-chip devices.

Main Methods:

  • Utilized upstream flow capacitance and thermal control of fluid viscosity.
  • Employed a PID-controlled restrictor-chip with a high-pressure-resistant microfluidic glass chip.
  • Integrated thin films for resistive heating, ensuring no moving parts.

Main Results:

  • Achieved significant stability improvement for ISCO, HPLC, and Harvard pumps.
  • ISCO pump demonstrated a relative precision of 0.035% and accuracy of 8.0 ppm.
  • The control algorithm compensated for pump inaccuracies, enhancing long-term stabilization.

Conclusions:

  • The developed stabilizer offers a new approach for precise microfluidic control.
  • Its low dead volume (16 nL) allows seamless integration into micro-total-analysis systems.
  • This innovation addresses a critical challenge in achieving reproducible microfluidic results.